Actisense EMU-1 Engine Monitoring Unit, Analogue to NMEA 2000
Actisense EMU-1 Engine Monitoring Unit, Analogue to NMEA 2000
Actisense
SKU:EMU-1-BAS
Delivery status: On order
Couldn't load pickup availability
Prices in EUR. Worldwide delivery, also to vessels. Payment, delivery and returns →
The EMU-1 converts the signals from a boat's analogue engine senders and gauges into NMEA 2000 data. Older engines can then show RPM, temperatures, pressures, fuel level, tilt/trim and alarms on a modern chart plotter or multifunction display, and the existing gauges can stay in place.
One unit can monitor up to two engines. It is a cost-effective way to bring legacy inboard or outboard engines onto an NMEA 2000 network. It works on 12 V and 24 V systems. Initial setup is done with an Actisense NGX-1 PC interface and the free Actisense Toolkit software.
- Inputs: 6 analogue gauge inputs, 4 alarm inputs and 2 tacho (RPM) inputs
- Tacho inputs work with ignition coil, alternator W/R/AC, hall effect and inductive senders
- Logs engine hours for 2 engines in non-volatile memory
- Power supply: 9–35 V DC (under 25 mA typical at 12 V), with reverse polarity and load dump protection
- NMEA 2000 port: M12 male A-coded, galvanically isolated, LEN 1
- Approvals: NMEA 2000 certified, EMC to EN 60945; IP65
- Polycarbonate housing, 127 × 106 × 48 mm; panel mounting with stainless screws included
- Description
The EMU-1 converts the signals from a boat's analogue engine senders and gauges into NMEA 2000 data. Older engines can then show RPM, temperatures, pressures, fuel level, tilt/trim and alarms on a modern chart plotter or multifunction display, and the existing gauges can stay in place.
One unit can monitor up to two engines. It is a cost-effective way to bring legacy inboard or outboard engines onto an NMEA 2000 network. It works on 12 V and 24 V systems. Initial setup is done with an Actisense NGX-1 PC interface and the free Actisense Toolkit software.
- Inputs: 6 analogue gauge inputs, 4 alarm inputs and 2 tacho (RPM) inputs
- Tacho inputs work with ignition coil, alternator W/R/AC, hall effect and inductive senders
- Logs engine hours for 2 engines in non-volatile memory
- Power supply: 9–35 V DC (under 25 mA typical at 12 V), with reverse polarity and load dump protection
- NMEA 2000 port: M12 male A-coded, galvanically isolated, LEN 1
- Approvals: NMEA 2000 certified, EMC to EN 60945; IP65
- Polycarbonate housing, 127 × 106 × 48 mm; panel mounting with stainless screws included
Share